{"id":195,"date":"2024-04-17T23:45:32","date_gmt":"2024-04-17T23:45:32","guid":{"rendered":"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/?page_id=195"},"modified":"2024-04-18T00:47:07","modified_gmt":"2024-04-18T00:47:07","slug":"design","status":"publish","type":"page","link":"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/design\/","title":{"rendered":"Design"},"content":{"rendered":"\n<p><strong>Initial Design Ideas<\/strong><\/p>\n\n\n\n<p><strong>Attachment Site Design Ideas <\/strong><\/p>\n\n\n\n<p>Design #1: Modified Condom Catheter<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"670\" height=\"448\" src=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-7.58.39-PM.png\" alt=\"\" class=\"wp-image-198\" style=\"width:509px;height:auto\" srcset=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-7.58.39-PM.png 670w, https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-7.58.39-PM-300x201.png 300w\" sizes=\"auto, (max-width: 670px) 100vw, 670px\" \/><\/figure><\/div>\n\n\n<p>Design 1 presents a condom catheter design featuring a thin layer of silicone and a volume for urine collection to the canister. Additionally, check valves are integrated to maintain proper vacuum flow direction.<\/p>\n\n\n\n<p><br>Design #2: Modified Head Condom Catheter<\/p>\n\n\n\n<p><em>Chosen Design Solution<\/em><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"728\" height=\"373\" src=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.00.34-PM-edited.png\" alt=\"\" class=\"wp-image-201\" style=\"width:564px;height:auto\" srcset=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.00.34-PM-edited.png 728w, https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.00.34-PM-edited-300x154.png 300w\" sizes=\"auto, (max-width: 728px) 100vw, 728px\" \/><\/figure><\/div>\n\n\n<p>The selected design solution, based on Design Idea 2 for the attachment site, integrates elements of the existing condom catheter design. It includes a larger volume and thicker area surrounding the penis head to facilitate urine collection, triggering the thermistor sensor for activating the house vacuum system.<\/p>\n\n\n\n<p>Design #3: Modified Bag Catheter <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"582\" height=\"722\" src=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.02.04-PM.png\" alt=\"\" class=\"wp-image-202\" style=\"width:404px;height:auto\" srcset=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.02.04-PM.png 582w, https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.02.04-PM-242x300.png 242w\" sizes=\"auto, (max-width: 582px) 100vw, 582px\" \/><\/figure><\/div>\n\n\n<p>Design 3 presents a modified bag catheter design featuring a non-agitative adhesive and a mesh-like fabric for urine wicking into the collection canister. Additionally, check valves are integrated to maintain proper vacuum flow direction.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>Canister Design Ideas <\/strong><\/p>\n\n\n\n<p>Design #1: Manual Line Switching<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"734\" height=\"424\" src=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.31-PM.png\" alt=\"\" class=\"wp-image-215\" style=\"width:673px;height:auto\" srcset=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.31-PM.png 734w, https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.31-PM-300x173.png 300w\" sizes=\"auto, (max-width: 734px) 100vw, 734px\" \/><\/figure>\n\n\n\n<p>Design #2: Double Line with Switching Urinalysis Cup<\/p>\n\n\n\n<p><em>Chosen Design Solution<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"812\" height=\"456\" src=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.46-PM.png\" alt=\"\" class=\"wp-image-216\" style=\"width:699px;height:auto\" srcset=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.46-PM.png 812w, https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.46-PM-300x168.png 300w, https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.46-PM-768x431.png 768w\" sizes=\"auto, (max-width: 706px) 89vw, (max-width: 767px) 82vw, 740px\" \/><\/figure>\n\n\n\n<p>Design #3: Integrated Urinalysis Cup with Alternating Valves <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"752\" height=\"460\" src=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.57-PM.png\" alt=\"\" class=\"wp-image-217\" style=\"width:688px;height:auto\" srcset=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.57-PM.png 752w, https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-content\/uploads\/sites\/253\/2024\/04\/Screen-Shot-2024-04-17-at-8.43.57-PM-300x184.png 300w\" sizes=\"auto, (max-width: 706px) 89vw, (max-width: 767px) 82vw, 740px\" \/><\/figure><\/div>","protected":false},"excerpt":{"rendered":"<p>Initial Design Ideas Attachment Site Design Ideas Design #1: Modified Condom Catheter Design 1 presents a condom catheter design featuring a thin layer of silicone and a volume for urine collection to the canister. Additionally, check valves are integrated to maintain proper vacuum flow direction. Design #2: Modified Head Condom Catheter Chosen Design Solution The &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/design\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Design&#8221;<\/span><\/a><\/p>\n","protected":false},"author":498,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-195","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-json\/wp\/v2\/pages\/195","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-json\/wp\/v2\/users\/498"}],"replies":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-json\/wp\/v2\/comments?post=195"}],"version-history":[{"count":0,"href":"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-json\/wp\/v2\/pages\/195\/revisions"}],"wp:attachment":[{"href":"https:\/\/engprojects.tcnj.edu\/modified-vac-assisted-male-external-catheter-system\/wp-json\/wp\/v2\/media?parent=195"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}