{"id":57,"date":"2022-11-07T23:35:15","date_gmt":"2022-11-07T23:35:15","guid":{"rendered":"https:\/\/engprojects.tcnj.edu\/neonest\/?page_id=57"},"modified":"2023-02-09T00:36:45","modified_gmt":"2023-02-09T00:36:45","slug":"design-controls","status":"publish","type":"page","link":"https:\/\/engprojects.tcnj.edu\/neonest\/design-controls\/","title":{"rendered":"Design Controls"},"content":{"rendered":"\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-1 wp-block-group-is-layout-flex\">\n<p>Design Input 1<\/p>\n\n\n\n<table id=\"tablepress-DI_1\" class=\"tablepress tablepress-id-DI_1 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Justification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Device must be transportable<\/td><td class=\"column-2\">a) Maximum weight of device is 16 kg<br \/>\nb) Device does not exceed dimensions of 109 cm length, 65.5 cm width, and 76 cm height<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">a) Suggested carrying weight at waist level for women is 16 kg [1]. Women typically can carry less than men so by using the lower weight suggestion a greater portion of the population is included<br \/>\nb) Dimensions of device are within average door size of target region [2] and comparable to transportable infant incubators in the US [3]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_1 from cache -->\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-2 wp-block-group-is-layout-flex\">\n<p>Design Input 2<\/p>\n\n\n\n<table id=\"tablepress-DI_2\" class=\"tablepress tablepress-id-DI_2 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Justification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Device must support infant weight<\/td><td class=\"column-2\">Device chamber must support up to 7 lbs<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">Device has to be able to support the weight of the infant developing inside the incubator without compromising structural integrity and risking user safety. Weight of a premature infant is between 1 - 5lbs and the average weight of a full-term infant is 7lbs [4]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_2 from cache -->\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-3 wp-block-group-is-layout-flex\">\n<p>Design Input 3<\/p>\n\n\n\n<table id=\"tablepress-DI_3\" class=\"tablepress tablepress-id-DI_3 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Specification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Device must maintain appropriate temperature range<\/td><td class=\"column-2\">Maintain internal chamber temperature between 36.5\u00b0C - 37.5\u00b0C<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">Deviating outside this range may result in hypothermia or fever for the infant user<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_3 from cache -->\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-4 wp-block-group-is-layout-flex\">\n<p>Design Input 4<\/p>\n\n\n\n<table id=\"tablepress-DI_4\" class=\"tablepress tablepress-id-DI_4 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Specification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Device must maintain appropriate humidity<\/td><td class=\"column-2\">Maintain relative humidity between 60% - 70%<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">Humidity range specified has been identified appropriate to protect infant skin, maintain body temperature, and prevent water loss [5]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_4 from cache -->\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-5 wp-block-group-is-layout-flex\">\n<p>Design Input 5<\/p>\n\n\n\n<table id=\"tablepress-DI_5\" class=\"tablepress tablepress-id-DI_5 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Specification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Device must measure\/sense incubator internal conditions<\/td><td class=\"column-2\">a) Sense temperature to \u00b1 0.5\u00b0C<br \/>\nb) Sense humidity to \u00b1 1%<br \/>\nc) Sense battery current charge to \u00b1 1%<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">Has to ensure that device will be able to provide an accurate measure for the internal conditions that will be showcased to the caregiver<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_5 from cache -->\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6 wp-block-group-is-layout-flex\">\n<p>Design Input 6<\/p>\n\n\n\n<table id=\"tablepress-DI_6\" class=\"tablepress tablepress-id-DI_6 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Specification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Device must have an audible and visual display\/alert system for internal conditions<\/td><td class=\"column-2\">a) Display parameter and value in plain text<br \/>\nb) Red, yellow, and green LED status indicators<br \/>\nc) Audible pattern for medium priority (intermittent) and high priority (sustained) alerts<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">b) Red, yellow, green indicators are commonly understood visual status markers [6] that will draw caregiver attention to display where further details of system intervention needs will allow caregiver to intervene as necessary<br \/>\nc) Audible pattern will adhere to internationally accepted sounds and patterns for medical monitoring [7]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_6 from cache -->\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-7 wp-block-group-is-layout-flex\">\n<p>Design Input 7<\/p>\n\n\n\n<table id=\"tablepress-DI_7\" class=\"tablepress tablepress-id-DI_7 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Specification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Device must operate at low appropriate sound level<\/td><td class=\"column-2\">Sound pressure level within the chamber is < 45 dB<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">American Association of Pediatrics determined  > 45 dB as level of concern for newborn hearing development damage [8]<br \/>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_7 from cache -->\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8 wp-block-group-is-layout-flex\">\n<p>Design Input 8<\/p>\n\n\n\n<table id=\"tablepress-DI_8\" class=\"tablepress tablepress-id-DI_8 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Specification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Device must maintain power supply necessary to operate for duration of use<\/td><td class=\"column-2\">a) Minimum power necessary for all components<br \/>\nb) Minimum duration of use is 2 hrs<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">Appropriate amount of current must run through each component for device to operate<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_8 from cache -->\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-9 wp-block-group-is-layout-flex\">\n<p>Design Input 9<\/p>\n\n\n\n<table id=\"tablepress-DI_9\" class=\"tablepress tablepress-id-DI_9 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Specification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Device must filter contaminants and airflow through the <\/td><td class=\"column-2\">a) Minimum filter efficiency of MERV - 14 [9]<br \/>\nb) Airflow of six changes per hour [10] - approximately 0.6 m^3\/h<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">a) MERV - 15 is the minimum filtration efficiency stated by NSI\/ASHRAE\/ASHE Standard<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_9 from cache -->\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-10 wp-block-group-is-layout-flex\">\n<p>Design Input 10<\/p>\n\n\n\n<table id=\"tablepress-DI_10\" class=\"tablepress tablepress-id-DI_10 tbody-has-connected-cells\">\n<tbody class=\"row-striping\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Requirement<\/td><td class=\"column-2\">Specification<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Components of device must be serviceable and replaceable within a reasonable timeframe<\/td><td class=\"column-2\">a) Must function for at least 2 hrs continuously without intervention<br \/>\nb) Function for up to 4 weeks before needing maintenance on system components<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td colspan=\"2\" class=\"column-1\">Justification<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td colspan=\"2\" class=\"column-1\">a) About 71% of the total population and 72% of women able to bear children live within 2 hours travel distance from the hospital [11], incubator should be able to support infant for duration of travel to next nearest level of care<br \/>\nb) Cargo may be backlogged for up to three week, unable to be delivered[12], serviceable parts should sustain until new parts are able to be delivered<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-DI_10 from cache -->\n<\/div>\n\n\n\n<pre class=\"wp-block-preformatted\">\n[1]What is the maximum weight limit I can lift at work? (n.d.). From https:\/\/www.beckettandco.co.uk\/manual-handling-faq-weight\/\n\n[2]What are the standard door sizes in your country? (2018, October 18). From https:\/\/www.doorsdirect.co.za\/what-are-the-standard-door-sizes-in-your-country\n\n[3]Equipment for the way you operate [Https:\/\/storage.googleapis.com\/avante\/documents\/dre_neoglider.pdf]. (n.d.). Louisville: DRE NeoGLIDER.\n\n[4]Caring for a premature baby: What parents need to know. (2019, October 31). Retrieved from https:\/\/www.healthychildren.org\/English\/ages-stages\/baby\/preemie\/Pages\/Caring-For-A-Premature-Baby.aspx#:~:text=Characteristics%20of%20Babies%20Born%20Premature,kg\n\n[5]Glass, L., &amp; Valdez, A. (2021). Preterm Infant Incubator Humidity Levels: A Systematic Review. Advances in neonatal care : official journal of the National Association of Neonatal Nurses, 21(4), 297\u2013307. https:\/\/doi.org\/10.1097\/ANC.0000000000000791\n\n[6]Neonatal guidelines 2022-2024. (2022). Retrieved from https:\/\/b-ok.cc\/book\/23052748\/5952b5\n\n[7]Schweber, B. (2020, July 22). How to properly implement audible alarms in medical monitoring. Retrieved from https:\/\/www.digikey.com\/en\/articles\/how-to-properly-implement-audible-alarms-in-medical-monitoring\n\n[8]Noise: A hazard for the fetus and newborn. (1997). Pediatrics, 100(4), 724-727. doi:10.1542\/peds.100.4.724\n\n[9]Ventilation of Health Care Facilities [PDF]. (2020, July 31). Atlanta: ASHRAE.\n\n[10]Neonatal guidelines 2022-2024. (2022). Retrieved from https:\/\/b-ok.cc\/book\/23052748\/5952b5\n\n[11]This is how far people in Africa have to travel to reach a hospital. (2018, September 26). From https:\/\/www.weforum.org\/agenda\/2018\/09\/people-across-africa-have-to-travel-far-to-get-to-a-hospital-we-worked-out-how-far\n\n[12]Raballand, G., &amp; Oliver, J. (2013, June 26). Why does cargo sit so long in African ports? not just poor infrastructure... poor incentives. From https:\/\/blogs.worldbank.org\/trade\/why-does-cargo-sit-so-long-african-ports-not-just-poor-infrastructure-poor-incentives<\/pre>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><\/h2>\n","protected":false},"excerpt":{"rendered":"<p>Design Input 1 Design Input 2 Design Input 3 Design Input 4 Design Input 5 Design Input 6 Design Input 7 Design Input 8 Design Input 9 Design Input 10 [1]What is the maximum weight limit I can lift at work? (n.d.). From https:\/\/www.beckettandco.co.uk\/manual-handling-faq-weight\/ [2]What are the standard door sizes in your country? (2018, October &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/engprojects.tcnj.edu\/neonest\/design-controls\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Design Controls&#8221;<\/span><\/a><\/p>\n","protected":false},"author":395,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-57","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/engprojects.tcnj.edu\/neonest\/wp-json\/wp\/v2\/pages\/57","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/engprojects.tcnj.edu\/neonest\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/engprojects.tcnj.edu\/neonest\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/neonest\/wp-json\/wp\/v2\/users\/395"}],"replies":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/neonest\/wp-json\/wp\/v2\/comments?post=57"}],"version-history":[{"count":0,"href":"https:\/\/engprojects.tcnj.edu\/neonest\/wp-json\/wp\/v2\/pages\/57\/revisions"}],"wp:attachment":[{"href":"https:\/\/engprojects.tcnj.edu\/neonest\/wp-json\/wp\/v2\/media?parent=57"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}