{"id":113,"date":"2022-01-31T16:43:15","date_gmt":"2022-01-31T16:43:15","guid":{"rendered":"https:\/\/engprojects.tcnj.edu\/rls-device\/?page_id=113"},"modified":"2022-04-09T13:30:10","modified_gmt":"2022-04-09T13:30:10","slug":"components","status":"publish","type":"page","link":"https:\/\/engprojects.tcnj.edu\/rls-device\/components\/","title":{"rendered":"Component(s)"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Electric Heating Pads:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"636\" src=\"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-18.01.59-1024x636.png\" alt=\"\" class=\"wp-image-160\" srcset=\"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-18.01.59-1024x636.png 1024w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-18.01.59-300x186.png 300w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-18.01.59-768x477.png 768w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-18.01.59-1536x954.png 1536w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-18.01.59.png 1678w\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Figure 1: Plot of Temperatures at Voltages of 4 (Orange), 4.06 (Green), and 4.15 (Blue). It was determined that a voltage of 4.06 was optimal, and this value was used to define relationships for the remaining heating temperatures as well as cooling. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thermistors:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"667\" src=\"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-17.33.33-1024x667.png\" alt=\"\" class=\"wp-image-158\" srcset=\"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-17.33.33-1024x667.png 1024w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-17.33.33-300x196.png 300w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-17.33.33-768x501.png 768w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-17.33.33-1536x1001.png 1536w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-08-at-17.33.33-2048x1335.png 2048w\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Figure 2: Calibration curves for ten 10k Epoxy Coated Thermistors. Ultimately, four sensors were designated for heating based on R-squared values. The equations for the selected thermistors were found separately and adjusted to fit the desired temperatures line. All adjustments were made within the code for the device.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"660\" src=\"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-09-at-09.29.05-1024x660.png\" alt=\"\" class=\"wp-image-161\" srcset=\"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-09-at-09.29.05-1024x660.png 1024w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-09-at-09.29.05-300x193.png 300w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-09-at-09.29.05-768x495.png 768w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-09-at-09.29.05-1536x990.png 1536w, https:\/\/engprojects.tcnj.edu\/rls-device\/wp-content\/uploads\/sites\/175\/2022\/04\/Screen-Shot-2022-04-09-at-09.29.05-2048x1319.png 2048w\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Figure 3: Calibration curves for seven 10k Epoxy Coated Thermistors. Similar to before, four sensors were designated for cooling based on R-squared values and the equations for these sensors were adjusted within the main code.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Electric Heating Pads: Figure 1: Plot of Temperatures at Voltages of 4 (Orange), 4.06 (Green), and 4.15 (Blue). It was determined that a voltage of 4.06 was optimal, and this value was used to define relationships for the remaining heating temperatures as well as cooling. Thermistors: Figure 2: Calibration curves for ten 10k Epoxy Coated &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/engprojects.tcnj.edu\/rls-device\/components\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Component(s)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":364,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-113","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-json\/wp\/v2\/pages\/113","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-json\/wp\/v2\/users\/364"}],"replies":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-json\/wp\/v2\/comments?post=113"}],"version-history":[{"count":0,"href":"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-json\/wp\/v2\/pages\/113\/revisions"}],"wp:attachment":[{"href":"https:\/\/engprojects.tcnj.edu\/rls-device\/wp-json\/wp\/v2\/media?parent=113"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}