{"id":163,"date":"2026-04-16T04:12:30","date_gmt":"2026-04-16T04:12:30","guid":{"rendered":"https:\/\/engprojects.tcnj.edu\/stepwise\/?page_id=163"},"modified":"2026-04-16T04:12:30","modified_gmt":"2026-04-16T04:12:30","slug":"hard-stop-verification-and-validation","status":"publish","type":"page","link":"https:\/\/engprojects.tcnj.edu\/stepwise\/hard-stop-verification-and-validation\/","title":{"rendered":"&#8212; Hard Stop Verification and Validation"},"content":{"rendered":"\n<p>Verification Testing:<\/p>\n\n\n\n<p>The device\u2019s fail-safe mechanism will be confirmed by attempting to rotate the device beyond the constrained range of motion and measuring further motion beyond that range.<\/p>\n\n\n\n<p>Validation Testing:<\/p>\n\n\n\n<p>Human testing will be used to confirm that the fail-safe prevents the device from rotating beyond the human ROM limits.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large wp-duotone-unset-1\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/engprojects.tcnj.edu\/stepwise\/wp-content\/uploads\/sites\/293\/2026\/04\/image-6-768x1024.jpeg\" alt=\"\" class=\"wp-image-164\" title=\"IMG_7602.jpeg\" srcset=\"https:\/\/engprojects.tcnj.edu\/stepwise\/wp-content\/uploads\/sites\/293\/2026\/04\/image-6-768x1024.jpeg 768w, https:\/\/engprojects.tcnj.edu\/stepwise\/wp-content\/uploads\/sites\/293\/2026\/04\/image-6-225x300.jpeg 225w, https:\/\/engprojects.tcnj.edu\/stepwise\/wp-content\/uploads\/sites\/293\/2026\/04\/image-6-1152x1536.jpeg 1152w, https:\/\/engprojects.tcnj.edu\/stepwise\/wp-content\/uploads\/sites\/293\/2026\/04\/image-6.jpeg 1536w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<p><em>Hard stop validation testing for the acute phase. Testing failed to meet specification of 0-5\u00b0 in plantar- and dorsiflexion.<\/em><br><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Verification Testing: The device\u2019s fail-safe mechanism will be confirmed by attempting to rotate the device beyond the constrained range of motion and measuring further motion beyond that range. Validation Testing: Human testing will be used to confirm that the fail-safe prevents the device from rotating beyond the human ROM limits. Hard stop validation testing for [&hellip;]<\/p>\n","protected":false},"author":664,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-163","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/engprojects.tcnj.edu\/stepwise\/wp-json\/wp\/v2\/pages\/163","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/engprojects.tcnj.edu\/stepwise\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/engprojects.tcnj.edu\/stepwise\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/stepwise\/wp-json\/wp\/v2\/users\/664"}],"replies":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/stepwise\/wp-json\/wp\/v2\/comments?post=163"}],"version-history":[{"count":0,"href":"https:\/\/engprojects.tcnj.edu\/stepwise\/wp-json\/wp\/v2\/pages\/163\/revisions"}],"wp:attachment":[{"href":"https:\/\/engprojects.tcnj.edu\/stepwise\/wp-json\/wp\/v2\/media?parent=163"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}