{"id":146,"date":"2024-02-11T18:31:49","date_gmt":"2024-02-11T18:31:49","guid":{"rendered":"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/?page_id=146"},"modified":"2024-05-01T22:16:37","modified_gmt":"2024-05-01T22:16:37","slug":"verification-validation-activities","status":"publish","type":"page","link":"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/verification-validation-activities\/","title":{"rendered":"Verification\/Validation Activities"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Verification Activities<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>1.1<\/td><td>Spectrophotometer will be used to measure the wavelength of both the red and near IR lights.<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" width=\"460px;\" height=\"270px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/mB6Uozp9CS2x1OA6pioTfFJF3jdh0b-owJHfOF_OOU0-8EtqJdpiuypkEWneICDXVmbdN_I_CE3vdO9Irn_6tFTDMjsvLUHoF5XjFbKXrDG-pBUjoJcrviF4XOmZNlAznhvBd6r2OefKp3y7g7kODLSbvA=s2048\"><br><img decoding=\"async\" width=\"463px;\" height=\"270px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/eLVxvzWLxyoX3yrCGbEFdUtJF6PYVO7PPRN-9hxZ2loaYMrmydDf8nQYvPTx46XQGNTqljBomfTUAVfHlPUByYGmSZpt8kLKbC046HlTR-qWQ6KvzyTbKSsuc1TJwt3saVtKzL2wLN9Vyrx6szJnYWYmsg=s2048\"><\/td><\/tr><tr><td>2.1<\/td><td>Use paint samples with given RGB corresponding to different wavelengths.<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" width=\"461px;\" height=\"306px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/loa7f0ntV-mLXo6LutGDQZNDiUYk5YIJCxm_pPqbYvNQ7QntDjcdnBm5fMLSaDZX9W4eZ3yU-JyYTqPTJJjx6sXlJGBEn8a4q801SeTpuH90l9oII8BH-oV9QnGUR5-BwLs4PWdJ67eKfT6CP62glBIaPw=s2048\"><br><img decoding=\"async\" width=\"374px;\" height=\"146px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/iTrqE-RXXHUv2UX401rOqDNxC5_UEFvsXvfNv1cSjsoE2AtUONwSXFiaHnBFx-jbDmx74YwQLJjfu28_y-GlsgwD1N20xbuxqXYHYpcVN8SLwVmkqcJUFM-A600EcbJ5Yj6xMtlkxi8lvtPP_QtrX_iGgg=s2048\"><\/td><\/tr><tr><td>3.1<\/td><td>Comparison of calculated SpO2 and known pulse oximeter. Model skin tone variance with pale-skinned subject. Test model skin at various SpO2 ranges by holding breath.<\/td><\/tr><tr><td>Fail<\/td><td><br><img decoding=\"async\" width=\"455px;\" height=\"273px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/wNrl19S93rkrHggfiBgAtEv18H6y6Hy45wzcsUDZrjp4EgspcyclKL2zq-CkcZ90sEQ0wNXNmA4VaCQUeklamVu-mhS6gvYv2RY2022JrPpwpzpxF_lauHeXf3Mlr7v0W2CMLt3LUajH41ZSHPbFUaCQLA=s2048\"><br><img decoding=\"async\" width=\"454px;\" height=\"273px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/-WWfR2YqS-MuFrlzL_G3ibhNgkbqUiKhsAn5LXBEwNqu__FOxEl9ERcwf0Uga2o5XwHA4jYtNqCNkAP2hFYAAsxJQio_HWQFad4QrGwOb65mw0g0l2p63mauizriMUCY4KZC-nciAzjB53cSvQX-euDyQw=s2048\"><br><img decoding=\"async\" width=\"429px;\" height=\"258px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/cAzTIjUaTXO_aPSyZr56vOHVoet6ydeDKj10CON_-EMwj6fPWyYZlPPrscLe323JkyuSx_chXEhBUX_l_2y8lcDpeafkm9xW-AeaBWQplJv3TTMbBqRignhPbaEd_KrwhOfzPmeucQBwK2BuOc8COJPzVQ=s2048\"><br><img decoding=\"async\" width=\"428px;\" height=\"241px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/E5TSZTOIejkAMlP1oXtANLaAZ9gqpA9Kd8NNIZPRBvaV4bViGMO6LugbCneSzUGEw2-XD09M7KcGLN1FSPHf1WHaAcq9GU1WtY2X_u09UWnUvsn2o48phzSn6uAjMZ3wd6cN7Epl6xv198v8k5U-23xY1Q=s2048\"><\/td><\/tr><tr><td>4.1<\/td><td>&nbsp;Manipulation of code to manually cause system alert<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" src=\"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-content\/uploads\/sites\/248\/2024\/05\/Screenshot-2024-05-01-at-5.56.24\u202fPM.png\" alt=\"\"><img decoding=\"async\" width=\"252px;\" height=\"305px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/LemGtq8I5y9mnBrhWJrP9pZ0wPYlgs9z9FvXRfuGQWxWaSM6UHbH2IhbYHuwgja1FgRyZ-uFPZRDzfZeFxg0Z3nxkls2USn1b1YSrIP3Xl7-ieIw8yg9wRXMBRSmC7gzg-bMEMaXKN_2jFc7oAQ-Iu8_nA=s2048\"><br><\/td><\/tr><tr><td>5.1<\/td><td>Measure with digital caliper<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" src=\"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-content\/uploads\/sites\/248\/2024\/05\/Screenshot-2024-05-01-at-5.57.43%E2%80%AFPM.png\" alt=\"This image has an empty alt attribute; its file name is Screenshot-2024-05-01-at-5.57.43%E2%80%AFPM.png\"><br><img decoding=\"async\" width=\"212px;\" height=\"284px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/qg5HSM0o0QOcqQaCe7w4w5oIZOjB3SpI4916zKYt_qxwHWTRe0hJ6HJWZGYeO3OcOibE57WDNOA06onTzi1pkox9evgllXDyvOa7LaVnpVYKX1hl5_MPhtob8PMI5skwC_oSaMLRAT7Z8FrPq5G6E1HvqA=s2048\"><\/td><\/tr><tr><td>6.1<\/td><td>Contrast Checker<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" width=\"305px;\" height=\"247px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/xa4kG__m71KnstbsZQJ2dOaSEf7zxisI743xHODCYkKVs_0l1s7TtpZxjMci0iVtgZrNWfao-YyjMVNU6rCv0OEl2eU-4gCvg0RYrIQIoUqLvUJltaQEklmCcuqgDGfzRXRWCj5vLbV1dKUvn1kGPd81ug=s2048\"><br><img decoding=\"async\" src=\"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-content\/uploads\/sites\/248\/2024\/05\/Screenshot-2024-05-01-at-5.59.47\u202fPM.png\" alt=\"\"><\/td><\/tr><tr><td>7.1<\/td><td>Leakage current test through analogous modeling of human body.<\/td><\/tr><tr><td>Fail<\/td><td><img decoding=\"async\" width=\"680px;\" height=\"336px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/RDHIAjK-NR7YjHMT-6mbUD6TwnZCHLLSeh40rpkoujnw4yogo-fEDZ3y-Fi7pU_Zsh4Bg5AzLvsN31KrKy6To4cveNFBwM-shoCupySQQFLbDYOwid8wuaP0fDBnm-3uz3FvVhl3wVEzYS2UG45-DMvFsQ=s2048\"><br><img decoding=\"async\" width=\"166px;\" height=\"274px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/mhCocUHWxD-UBjXP0EDMhHCEn77nsIW6Il47XPlqq2pDBL2V7FBaqHhKHEQgm6-qpbo_y0NBVxAeu9gshFb0CEUsPctHAlmLrVBdCc7ToUCeS4KqvsN-IrtbSAojOjom-dVrjkyekMkxZD2enDh1ps9ZKA=s2048\"><\/td><\/tr><tr><td>8.1<\/td><td>Measure battery voltage and compare to needed<\/td><\/tr><tr><td>Pass<\/td><td>Correctly measured voltage<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Validation Activities<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>1.1<\/td><td>SpO<sub>2<\/sub> sensor outputting measurements based off of finger recording<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" width=\"429px;\" height=\"258px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/SqSZShJP9IHHJlnXnphx2q4R6lxr6ObyCKp6jT6VsV2w5UyZUUA-lp7nQP6OVNtpIftzlmwDXHsCmB5NWRH01kS9CmIxostjraUS56V1CK-L9bUsEPyXgXBwxA3iQK7AE-58Gn6lQxcg66p4I5pbNoQg9A=s2048\"><img decoding=\"async\" width=\"429px;\" height=\"258px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/E7egs0CEajEzDQ29RA8ITHJG3XA3aiAIahLDtcb6ZR-dQq2UIhBNNIGI8aWEIjEbixaPnP0iH5eAxIzLFgyjrbHGkSyr6ZUm7r27F-x3jrro_JLfgpZXWrErMN5di_hCHU_wOEg5T3x4eAeIKMI-NLM4RQ=s2048\"><\/td><\/tr><tr><td>2.1<\/td><td>Device color recognition test with subjects of different skin tones<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" width=\"308px;\" height=\"321px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/hYupDMzOcsi7HJsAi1YAFB5OxdmsHBjAuTToEDeKu18jfCQ19z-0CvJLqpMti9vE2MZGvNg85sp2QqPSadBHpoC-iXmvGpKLMcac-sDSgpCw2EWLLkORnG1rvjI9asB4yeRjYjmpgyHt5h4DnxGRC80ZKw=s2048\"><br><img decoding=\"async\" src=\"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-content\/uploads\/sites\/248\/2024\/05\/Screenshot-2024-05-01-at-5.56.47\u202fPM.png\" alt=\"\"><\/td><\/tr><tr><td>3.1<\/td><td>Test model skin at various SpO2 ranges by holding breath<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" width=\"407px;\" height=\"134px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/UWDVMR-cPHpUz2_DcW46tlK3zulfD3kGqwpP35XX3_e79nrVMmV9c_83wTFQjYVTmQlC3wAwUlUTaDo8_fuNdO7fRPxWiu-8PrKEVlZexLYOou1OCl5Bmj6oqAplwHaP0rWqxDEUr9sr72osdXl5ngUSJQ=s2048\"><br><img decoding=\"async\" width=\"412px;\" height=\"134px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/_twPTlePZrUTI1P0upInC-5EIqtW3pY45_hbnOnLWfhW_C5AoPCrmWPgNPRO5w549mig0Rtz8OeMdzgNlm4PeUs4W1vSr3P0vHcZXvp1tWAsjs-uGHJxlCj8tUZHmHFk01PE3pR0xF60sIt5K_nmJ-YOOw=s2048\"><\/td><\/tr><tr><td>4.1<\/td><td>User holds breath until SpO<sub>2<\/sub> measures less than 95%, inducing the alert<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" width=\"526px;\" height=\"326px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/TuoaKYJ7_gfOVnjK9LZOWHU9ebdwxUcH2YX7ymCj1ExwntCzDCTVNAY5eh6CuylIgGvq-gZO7FUR_Jj9TLOSP_bg1bKI2aOntdBX_bWOTVdwfk7f_vjNg_LOFpVG7ll6dv_1CLzLSTWPk1TM0itAs6nDpA=s2048\"><\/td><\/tr><tr><td>5.1<\/td><td>Survey users on comfort<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" width=\"538px;\" height=\"333px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/BwTU-ve7ULcxak7tA8OVU199oX1kX8I8iaFGAWrcg2RVvPAHfFVXNto97fbTaszyJCHC4-a5E7Thpm3hc0LPL0UCh_3OfvmoRj5hPFRkz6-OgDFJ6TgNf9bZLCRo3S-lCdGwHuzsrRhSo1IeM-MoZmhvVA=s2048\"><\/td><\/tr><tr><td>6.1<\/td><td>Survey on \u201cuser-friendly\u201d<\/td><\/tr><tr><td>Pass<\/td><td><img decoding=\"async\" width=\"534px;\" height=\"330px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/U0lGqIVk0CrBFewouuz7fU3GTKyc1cTAeP3nza1KqNLKBnzJYUaQ-C9ItssqDG0Uz7Xv3PUVwraiif_WvLSn4DLxxCsRpVCpH1hcIDJhWQDNAkYHCB6kmCXvX5ufHXyiN6T6SfJhcZ9ifAWmR-tOnGwK6A=s2048\"><\/td><\/tr><tr><td>7.1<\/td><td>Same as verification<\/td><\/tr><tr><td>Fail<\/td><td><img decoding=\"async\" width=\"680px;\" height=\"336px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/RDHIAjK-NR7YjHMT-6mbUD6TwnZCHLLSeh40rpkoujnw4yogo-fEDZ3y-Fi7pU_Zsh4Bg5AzLvsN31KrKy6To4cveNFBwM-shoCupySQQFLbDYOwid8wuaP0fDBnm-3uz3FvVhl3wVEzYS2UG45-DMvFsQ=s2048\"><br><img decoding=\"async\" width=\"166px;\" height=\"274px;\" src=\"https:\/\/lh7-us.googleusercontent.com\/mhCocUHWxD-UBjXP0EDMhHCEn77nsIW6Il47XPlqq2pDBL2V7FBaqHhKHEQgm6-qpbo_y0NBVxAeu9gshFb0CEUsPctHAlmLrVBdCc7ToUCeS4KqvsN-IrtbSAojOjom-dVrjkyekMkxZD2enDh1ps9ZKA=s2048\"><\/td><\/tr><tr><td>8.1<\/td><td>Measure voltage before\/after use<\/td><\/tr><tr><td>Pass<\/td><td>Correctly measured voltage<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Verification Activities 1.1 Spectrophotometer will be used to measure the wavelength of both the red and near IR lights. Pass 2.1 Use paint samples with given RGB corresponding to different wavelengths. Pass 3.1 Comparison of calculated SpO2 and known pulse oximeter. Model skin tone variance with pale-skinned subject. Test model skin at various SpO2 ranges &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/verification-validation-activities\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Verification\/Validation Activities&#8221;<\/span><\/a><\/p>\n","protected":false},"author":493,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-146","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-json\/wp\/v2\/pages\/146","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-json\/wp\/v2\/users\/493"}],"replies":[{"embeddable":true,"href":"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-json\/wp\/v2\/comments?post=146"}],"version-history":[{"count":0,"href":"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-json\/wp\/v2\/pages\/146\/revisions"}],"wp:attachment":[{"href":"https:\/\/engprojects.tcnj.edu\/stspulseoximeter\/wp-json\/wp\/v2\/media?parent=146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}